NCD Valve Trays
The NCD valve is a 2 piece valve, where a 4-legged hold down cage (securely attached to the tray deck) contains a movable valve disc.
These valves are used for general applications like the STD valve but with the following advantages:
- longer lasting in service
- less risk of sticking shut or open
- suitable for fouling services
- increased flexibility due to less liquid weeping
Alternate rows of light (1.5mm thick) and heavy (2.0mm thick) discs can be used to maximise turndown.
LCD Valve Trays
These are NCD valves with a very light disc (1.2mm thick) to reduce (dry) pressure drop.
VCD Valve Trays
These are NCD valves with a very light disc (1.2mm thick) plus a venturi hole to minimise (dry) pressure drop.